The Dp50rb Diaries
The Dp50rb Diaries
Blog Article
Assist 4D probe; identify the probe via the ID code; change the 4D push signal by way of the electrical relay to help make the 4D probe function Commonly. 4.two.2 Major board The principle board can be divided into two parts: front-close of the leading board and back-close of the principle board.
The person will not be allowed to open the addresses and panel of the procedure, neither Observe: product disassemble is allowed. To ensure the system efficiency and protection, only Mindray engineers or engineers authorized by Mindray can carry out upkeep.
Get a complete and prolonged look at with the anatomical framework by panoramic imaging coupled with velocity sign and forward/backward scan ability making scanning less difficult, smoother and even more controllable.
This manual might referring to information secured by copyright or patents and isn't going to Express any license under the patent legal rights or copyright of Mindray, or of Many others. Site 9: Statement
Simply click Agree and Move forward to simply accept cookies and go on to the internet site or click Additional information to determine in-depth descriptions of the categories of cookies and select no matter whether to simply accept specified cookies whilst on the location.
Once you end the scanning along with the impression capture, you'll want to electrical power off the method and disconnect the procedure with the AC electrical power source, then pull out AC electrical power cables. Web page 109: Battery Connecting Board
The chapter materials the tactic to verify main operate and efficiency of products. This really is only utilized for reference, not preventive execution. Purpose examining and tests of this section shall be carried out by Mindray support engineers along with the person with each other. Web site sixty six: Normal Test
Discover much better diagnostic information and facts by prolonged see of your anatomical composition on all convex probes.
Assessing clients in currently’s demanding ecosystem necessitates ground breaking know-how that permits clinicians to produce rapid and self-assured diagnoses. The flexibility with the DP-50 expands your clinical utility when assisting to make improvements to patient care.
5.2.three Geometric positioning precision Longitudinal geometric positioning accuracy Take a look at Phase: Do adjustments as the way in which in tests the maximum depth. Record the gap by 20mm Each and every phase around the longitudinal targets line using the measurement caliper; Pick out the value with the greatest mistake (to 20mm), work out the accuracy utilizing the formulation below The measurement caliper really should be positioned in the upper edge of the concentrate on, Take note:... Web page seventy nine Transverse geometric positioning accuracy Check Move: Protect the scan area with the phantom with drinking water or couple gel, Carefully Get in touch with the probe Together with the scan surface area Regulate the depth, making the transverse targets to generally be exhibited inside the image. Adjust the main focus level to generally be posited beside the transverse targets (the common is not really clear) Change parameters like gain, TGC, generating Just about every transverse targets for being Obviously shown. Web site eighty 5.5.2.four Blackout Area Test Move: Go over the scan floor of your phantom with h2o or pair gel, Carefully Get hold of the probe While using the scan surface Modify the depth in a reduce benefit, and set the main target at the closest destination to the scan surface area. Reduce the value of parameters like AP, Get till the track record sounds just can be seen. Site eighty one: Program Up grade And Routine maintenance
Kebutuhan Anda akan alat profesional dan canggih yang dikombinasikan dengan pencitraan berkualitas dan kemudahan kegunaan kini dapat dipenuhi dengan sistem portabel baru Mindray DP-50Exp.
Notice: Ahead of uploading the log, make certain the ultrasound system continues to be connected to community, otherwise, the program may well warn “could not connect to server” The server (smtp.
Cookies are essential to the correct performing of a web-site. To help your expertise, we use cookies to recall log-in aspects and provide secure log-in, gather figures to improve web-site features, and supply information customized in your interests.
Your Resource for further Dp50rb biopsy: permitting changes to your scan line to gain superior visibility with the needle, nerves and tiny vessels, guaranteeing the continuity of all data.
Take note: Be certain that you can pull out and thrust into the IO board sockets vertically when pulling out and assembling the IO board assembly about the posture in the cope with. Remove panhead screws with washers M3X6 (4) accustomed to safe the IO board, and then you could potentially get out the IO board. Site 116 Take out panhead screws with washers (two M3X6) which can be fastened on the most crucial device, take out the higher baffle and after that pull out two cables connecting the primary board to the power module assembly.